SGI Onyx

Hostname: rubens   Hostaddress: 192.168.1.29
Hardware: SGI Onyx RealityEngine 2
Software: IRIX 6.5.22
Owned since: 10. May 2003

description hinv pictures links

 Description:
System   SGI Onyx   Drives   4GB Harddisk
Processor   4xR4400 at 250MHz   Graphics   Reality Engine 2
Memory   512MB   Other   none

Installed Boardset

Slot Name Number Function
1 MC3 030-0604-00 Memory Board with 512MB
2 IP19 030-0804-101 CPU Board with 4 R4400 with 4MB cache each
3 IO4B 030-0646-106 IO Controller
4 VCAM 030-0243-00x VME Bridge
5 VME empty  
6 VME empty  
7 VME empty  
8 GE10 030-0325-005 Rev B Geometrie Engine
9 DG2 030-0513-005 Rev A Display Generator
10 RM4 empty  
11 RM4 030-0359-001 Rev C Raster Manager
12 RM4 empty  
13 RM4 030-0359-001 Rev C Raster Manager

Finally I managed to upgrade to Onyx from IP19 Quad-R4400@250MHz to IP25 Quad-R10000@194MHz. And it was really worth the money! See here for the current config.

See my page for general information on Onyxs

 hinv Output:

With Quad R4400

onyx 2# hinv -mv
CPU Board at Slot 2: (Enabled)
  Processor 0 at Slot 2/Slice 0: 250 Mhz R4400 with 4 MB secondary cache (Enabled)
  Processor 1 at Slot 2/Slice 1: 250 Mhz R4400 with 4 MB secondary cache (Enabled)
  Processor 2 at Slot 2/Slice 2: 250 Mhz R4400 with 4 MB secondary cache (Enabled)
  Processor 3 at Slot 2/Slice 3: 250 Mhz R4400 with 4 MB secondary cache (Enabled)
CPU: MIPS R4400 Processor Chip Revision: 6.0
FPU: MIPS R4000 Floating Point Coprocessor Revision: 0.0
Main memory size: 512 Mbytes, 2-way interleaved
MC3 Memory Board at Slot 1: 512 MB of memory (Enabled)
  Bank A contains 16 MB SIMMS (Enabled)
  Bank B contains 16 MB SIMMS (Enabled)
  Bank C contains 16 MB SIMMS (Enabled)
  Bank D contains 16 MB SIMMS (Enabled)
  Bank E contains 16 MB SIMMS (Enabled)
  Bank F contains 16 MB SIMMS (Enabled)
  Bank G contains 16 MB SIMMS (Enabled)
  Bank H contains 16 MB SIMMS (Enabled)
Instruction cache size: 16 Kbytes
Data cache size: 16 Kbytes
Secondary unified instruction/data cache size: 4 Mbytes
Integral SCSI controller 0: Version WD33C95A, single ended, revision 0
  CDROM: unit 6 on SCSI controller 0
Integral SCSI controller 1: Version WD33C95A, differential, revision 0
  Disk drive: unit 1 on SCSI controller 1 (unit 1)
  Disk drive: unit 2 on SCSI controller 1 (unit 2)
Integral EPC serial ports: 4
Integral EPC parallel port: Ebus slot 3
RealityEngineII Graphics Pipe 0 at IO Slot 3 Physical Adapter 2 (Fchip rev 2)
Integral Ethernet controller: et0, Ebus slot 3
I/O board, Ebus slot 3: IO4 revision 1
VME bus: adapter 13
VME bus: adapter 0 mapped to adapter 13
EPC external interrupts

onyx 3# /usr/gfx/gfxinfo -v
Graphics board 0 is "REV" graphics.
        Managed (":0.0") 1280x1024
        Display 1280x1024 @ 60Hz
        12 GE (GE10 rev. 0x7/011)
        2 RM4 boards (rev. 00112/00112)
        Medium pixel depth
        10-bit RGBA pixels
        Not using Multi-Channel Option
 Pictures:

The opened Cardcage

Edge Connector for graphics system

Edge Connector for graphics system

DG2 - Display Generator

DG2 - Display Generator

RM4 - Raster Manager

GE10 - Geometry Engine

IO4 - IO Board with VCAM

IO4 - IO Board with VCAM

SCSI-Connectors on IO4

IP19 - Quad R440 at 250 MHz

IP19 - Quad R440 at 250 MHz

IP25 - Quad R10000 at 194 MHz

IP25 - Quad R10000 at 194 MHz

IP25 - Quad R10000 at 194 MHz

MC3 - 512MB RAM

MC3 - 512MB RAM
 Links: